Edwardsiella Tarda antibody | 236/128

No associated image currently available
Mouse anti Edwardsiella tarda antibody, clone 236/128 recognizes Edwardsiella tarda.
E. tarda is a member of the family Enterobactericeae associated with freshwater ecosystems and is a causitive agent of gastoenteritis, wound infections and death due to septicaemia. It is thought that the pathogenicity of this bacteria is due to it's ability to resist phagocytic killing by the host defences. Replication of E. tarda in murine macrophages is dependant on the type III secretion system and induces an anti-apoptotic effect by up-regulating anti-apoptotic NF-kB target genes.
E. tarda is a member of the family Enterobactericeae associated with freshwater ecosystems and is a causitive agent of gastoenteritis, wound infections and death due to septicaemia. It is thought that the pathogenicity of this bacteria is due to it's ability to resist phagocytic killing by the host defences. Replication of E. tarda in murine macrophages is dependant on the type III secretion system and induces an anti-apoptotic effect by up-regulating anti-apoptotic NF-kB target genes.
Product Details
- Target Species
- Bacterial
- Product Form
- Purified IgG - liquid
- Preparation
- Purified IgG prepared by affinity chromatography on Protein G from tissue culture supernatant
- Buffer Solution
- Phosphate buffered saline
- Preservative Stabilisers
0.09% Sodium Azide (NaN3) - Carrier Free
- Yes
- Immunogen
- Native Edwardsiella tarda preparation.
- Approx. Protein Concentrations
- 1.0 mg/ml
Storage Information
- Storage
- Store at +4oC or at -20oC if preferred.
Storage in frost-free freezers is not recommended.
This product should be stored undiluted. Avoid repeated freezing and thawing as this may denature the antibody. Should this product contain a precipitate we recommend microcentrifugation before use. - Shelf Life
- 18 months from date of despatch.
More Information
- Regulatory
- For research purposes only
Applications of Edwardsiella Tarda antibody
Application Name | Verified | Min Dilution | Max Dilution |
---|---|---|---|
ELISA |
Where this product has not been tested for use in a particular technique this does not necessarily exclude its use in such procedures. Suggested working dilutions are given as a guide only. It is recommended that the user titrates the product for use in their own system using the appropriate negative/positive controls.
Copyright © 2019 Bio-Rad Antibodies (formerly AbD Serotec)
Secondary Antibodies Available
Product Specific References
References for Edwardsiella Tarda antibody
-
Hong, S.R. et al. (2009) Development of QCM biosensor to detect a marine derived pathogenic bacteria Edwardsiella tarda using a novel immobilisation method.
Biosens Bioelectron. 24: 1635-40.