Protocol: PK Bridging ELISA for Use with Anti-Dupilumab Antibodies
Protocol: PK Bridging ELISA for Use with Anti-Dupilumab Antibodies
Download PDF
For Use with Anti-Dupilumab Monoclonal Antibodies catalog TZA016 and TZA017 coupled to a suitable SpyCatcher Reagent (e.g. TZC002P)
This method provides a procedure for carrying out a PK ELISA with Anti-Dupilumab Antibody, TZA016 (capture antibody) and TZA017 (detection antibody) coupled to a suitable SpyCatcher Reagent and using dupilumab for the standard curve. The method should always be used in conjunction with product and batch specific information provided with each vial (see product datasheets). This protocol will need to be adjusted for use with different detection methods and immunoassay technology platforms.technology platforms.
View all of our dupilumab antibodies