    Product CodeApplicationsDatasheetMSDSPack SizeList PriceQuantity
    LNK252RHOCJdatasheet pdfdatasheet pdf datasheet pdf datasheet pdf1 Conjugation For 2mg Antibody
    LNK252RHO
    LNK253RHOCJdatasheet pdfdatasheet pdf datasheet pdf datasheet pdf3 Conjugations For 20µg Antibody
    LNK253RHO
    LNK251RHOCJdatasheet pdfdatasheet pdf datasheet pdf datasheet pdf3 Conjugations For 200µg Antibody
    LNK251RHO
    Summary
    Secondary Antibodies
    Negative Isotype Controls
    Useful Reagents
    Positive Controls
    Histology Controls
    More Images
    References
    Reviews
    -
    • Lynx Rapid Plus Rhodamine antibody conjugation kit™ enables the ultra rapid conjugation of a pre-prepared lyophilized mixture containing Rhodamine label to an antibody or protein. Activation of proprietary reagents within the antibody-label solution results in the coupling of Rhodamine to the antibody.

      The LYNX Rapid Plus kit™ can be used to label small quantities of antibody/protein at near neutral pH, allowing a high conjugation efficiency with 100% antibody recovery.
    • Intended Use
    • Product Form
    • Reconstitution
    • Preparation
    • Preservative Stabilisers
    • Purity
    • Approx. Protein Concentrations
    • Reagents In The Kit
      Pack Size: 3 Conjugations For 20µg Antibody, 3 Conjugations For 200µg Antibody3 Vials LYNXTM Rapid Plus lyophilized Rhodamine mix
      1 Vial LYNXTM Rapid Plus Modifier reagent
      1 Vial LYNXTM Rapid Plus Quencher reagent
      Pack Size: 1 Conjugation For 2mg Antibody1 Vial LYNXTM Rapid Plus lyophilized Rhodamine mix
      1 Vial LYNXTM Rapid Plus Modifier reagent
      1 Vial LYNXTM Rapid Plus Quencher reagent
      Pack Size: 3 Conjugations For 20µg Antibody, 3 Conjugations For 200µg Antibody3 Vials LYNXTM Rapid Plus lyophilized Rhodamine mix
      1 Vial LYNXTM Rapid Plus Modifier reagent
      1 Vial LYNXTM Rapid Plus Quencher reagent
      Pack Size: 1 Conjugation For 2mg Antibody1 Vial LYNXTM Rapid Plus lyophilized Rhodamine mix
      1 Vial LYNXTM Rapid Plus Modifier reagent
      1 Vial LYNXTM Rapid Plus Quencher reagent
      Pack Size: 3 Conjugations For 20µg Antibody, 3 Conjugations For 200µg Antibody3 Vials LYNXTM Rapid Plus lyophilized Rhodamine mix
      1 Vial LYNXTM Rapid Plus Modifier reagent
      1 Vial LYNXTM Rapid Plus Quencher reagent
      Pack Size: 1 Conjugation For 2mg Antibody1 Vial LYNXTM Rapid Plus lyophilized Rhodamine mix
      1 Vial LYNXTM Rapid Plus Modifier reagent
      1 Vial LYNXTM Rapid Plus Quencher reagent
    • Preparing The Antibody
      Pack Size: 3 Conjugations For 20µg AntibodyThe following buffer solutions are recommended:for preparing the antibody:

      10-50mM amine-free buffer (e.g HEPES, MES, MOPS and phosphate) pH range 6.5-8.5.

      Do not use buffers containing nucleophilic components e.g primary amines and thiols since they may react with LYNXTM chemicals, and Thiomersal should also be avoided. Azide (0.02-0.1%), BSA (0.1-0.5%), EDTA, Glycerol (up to 50%), and common non-buffering salts and sugars have little or no effect on conjugation efficiency.

      It is recommended that 10-20ug antibody be used in each labelling reaction. For optimal results the antibody volume should be 4-10ul, at a concentration range of 1-4mg/ml.
      Pack Size: 3 Conjugations For 200µg AntibodyThe following buffer solutions are recommended:for preparing the antibody:

      10-50mM amine-free buffer (e.g HEPES, MES, MOPS and phosphate) pH range 6.5-8.5.

      Do not use buffers containing nucleophilic components e.g primary amines and thiols since they may react with LYNXTM chemicals, and Thiomersal should also be avoided. Azide (0.02-0.1%), BSA (0.1-0.5%), EDTA, Glycerol (up to 50%), and common non-buffering salts and sugars have little or no effect on conjugation efficiency.

      It is recommended that 100-200ug antibody be used in each labelling reaction. For optimal results the antibody volume should be 40-100ul, at a concentration range of 1-4mg/ml.
      Pack Size: 1 Conjugation For 2mg AntibodyThe following buffer solutions are recommended:for preparing the antibody:

      10-50mM amine-free buffer (e.g HEPES, MES, MOPS and phosphate) pH range 6.5-8.5.

      Do not use buffers containing nucleophilic components e.g primary amines and thiols since they may react with LYNXTM chemicals, and Thiomersal should also be avoided. Azide (0.02-0.1%), BSA (0.1-0.5%), EDTA, Glycerol (up to 50%), and common non-buffering salts and sugars have little or no effect on conjugation efficiency.

      It is recommended that 1-2mg antibody be used in each labelling reaction. For optimal results the antibody volume should be 400-1000ul, at a concentration range of 1-4mg/ml.
      Pack Size: 3 Conjugations For 20µg AntibodyThe following buffer solutions are recommended:for preparing the antibody:

      10-50mM amine-free buffer (e.g HEPES, MES, MOPS and phosphate) pH range 6.5-8.5.

      Do not use buffers containing nucleophilic components e.g primary amines and thiols since they may react with LYNXTM chemicals, and Thiomersal should also be avoided. Azide (0.02-0.1%), BSA (0.1-0.5%), EDTA, Glycerol (up to 50%), and common non-buffering salts and sugars have little or no effect on conjugation efficiency.

      It is recommended that 10-20ug antibody be used in each labelling reaction. For optimal results the antibody volume should be 4-10ul, at a concentration range of 1-4mg/ml.
      Pack Size: 3 Conjugations For 200µg AntibodyThe following buffer solutions are recommended:for preparing the antibody:

      10-50mM amine-free buffer (e.g HEPES, MES, MOPS and phosphate) pH range 6.5-8.5.

      Do not use buffers containing nucleophilic components e.g primary amines and thiols since they may react with LYNXTM chemicals, and Thiomersal should also be avoided. Azide (0.02-0.1%), BSA (0.1-0.5%), EDTA, Glycerol (up to 50%), and common non-buffering salts and sugars have little or no effect on conjugation efficiency.

      It is recommended that 100-200ug antibody be used in each labelling reaction. For optimal results the antibody volume should be 40-100ul, at a concentration range of 1-4mg/ml.
      Pack Size: 1 Conjugation For 2mg AntibodyThe following buffer solutions are recommended:for preparing the antibody:

      10-50mM amine-free buffer (e.g HEPES, MES, MOPS and phosphate) pH range 6.5-8.5.

      Do not use buffers containing nucleophilic components e.g primary amines and thiols since they may react with LYNXTM chemicals, and Thiomersal should also be avoided. Azide (0.02-0.1%), BSA (0.1-0.5%), EDTA, Glycerol (up to 50%), and common non-buffering salts and sugars have little or no effect on conjugation efficiency.

      It is recommended that 1-2mg antibody be used in each labelling reaction. For optimal results the antibody volume should be 400-1000ul, at a concentration range of 1-4mg/ml.
      Pack Size: 3 Conjugations For 20µg AntibodyThe following buffer solutions are recommended:for preparing the antibody:

      10-50mM amine-free buffer (e.g HEPES, MES, MOPS and phosphate) pH range 6.5-8.5.

      Do not use buffers containing nucleophilic components e.g primary amines and thiols since they may react with LYNXTM chemicals, and Thiomersal should also be avoided. Azide (0.02-0.1%), BSA (0.1-0.5%), EDTA, Glycerol (up to 50%), and common non-buffering salts and sugars have little or no effect on conjugation efficiency.

      It is recommended that 10-20ug antibody be used in each labelling reaction. For optimal results the antibody volume should be 4-10ul, at a concentration range of 1-4mg/ml.
      Pack Size: 3 Conjugations For 200µg AntibodyThe following buffer solutions are recommended:for preparing the antibody:

      10-50mM amine-free buffer (e.g HEPES, MES, MOPS and phosphate) pH range 6.5-8.5.

      Do not use buffers containing nucleophilic components e.g primary amines and thiols since they may react with LYNXTM chemicals, and Thiomersal should also be avoided. Azide (0.02-0.1%), BSA (0.1-0.5%), EDTA, Glycerol (up to 50%), and common non-buffering salts and sugars have little or no effect on conjugation efficiency.

      It is recommended that 100-200ug antibody be used in each labelling reaction. For optimal results the antibody volume should be 40-100ul, at a concentration range of 1-4mg/ml.
      Pack Size: 1 Conjugation For 2mg AntibodyThe following buffer solutions are recommended:for preparing the antibody:

      10-50mM amine-free buffer (e.g HEPES, MES, MOPS and phosphate) pH range 6.5-8.5.

      Do not use buffers containing nucleophilic components e.g primary amines and thiols since they may react with LYNXTM chemicals, and Thiomersal should also be avoided. Azide (0.02-0.1%), BSA (0.1-0.5%), EDTA, Glycerol (up to 50%), and common non-buffering salts and sugars have little or no effect on conjugation efficiency.

      It is recommended that 1-2mg antibody be used in each labelling reaction. For optimal results the antibody volume should be 400-1000ul, at a concentration range of 1-4mg/ml.
    • Test Principle
    • Buffer Solution
    • Storage
      Store kit at -20oC only.
      Newly-conjugated antibody can be stored at 4oC. For long term storage however, the addition of a preservative is recommended.
      Storage in frost-free freezers is not recommended.
      This product should be stored undiluted.
      Avoid repeated freezing and thawing.
      Store kit at -20oC only.
      Newly-conjugated antibody can be stored at 4oC. For long term storage however, the addition of a preservative is recommended.
      Storage in frost-free freezers is not recommended.
      This product should be stored undiluted.
      Avoid repeated freezing and thawing.
      Store kit at -20oC only.
      Newly-conjugated antibody can be stored at 4oC. For long term storage however, the addition of a preservative is recommended.
      Storage in frost-free freezers is not recommended.
      This product should be stored undiluted.
      Avoid repeated freezing and thawing.
    • Shelf Life
      12 months after despatch
      12 months after despatch
      12 months after despatch
    • Acknowledgements
    • Licensed Use
      Bio-Rad LYNXTM conjugation kits are offered for research purposes alone, and are not intended for human, therapeutic or diagnostic use. The purchase of this conjugation kit conveys to the buyer (whether the buyer is a not-for-profit, academic or for-profit entity) the non-transferable right to use the amount of product purchased and the components of the product for in-house research. The buyer shall not sell or otherwise transfer this product, its components, or materials prepared therefrom to any third party. The buyer shall not use this product or its components for commercial purposes. For the avoidance of doubt, ‘commercial purposes’ means any activity by a party for consideration and includes, without limitation, use of the product or its components (i) in the manufacturing of conjugated materials (e.g. labeled antibodies), (ii) to provide a service, information or data, (iii) for therapeutic, diagnostic or prophylactic purposes, or (iv) for repackaging/resale, whether or not such product or its components are resold for use in research. The use of this product by the buyer constitutes agreement with the terms of this limited use label license for LYNXTM products.
    • Regulatory
      For research purposes only
    • This product has been reported to work in the following applications. This information is derived from testing within our laboratories, peer-reviewed publications or personal communications from the originators. Please refer to references indicated for further information. For general protocol recommendations, please visit the antibody protocols page.

    • Application NameYesNoMin DilutionMax Dilution
      Conjugation
    • Application NameYesNoMin DilutionMax Dilution
      Conjugation
    • Application NameYesNoMin DilutionMax Dilution
      Conjugation

    • We recommend that for each conjugation the user determines the best antibody:conjugate ratio.
    • Technical Advice
    • Technical Advice
    • Technical Advice
    • Recommended Protocol
    • Recommended Protocol
    • Recommended Protocol
    • ELISA
    • ELISA
    • ELISA
    • Immunohistology
    • Immunohistology
    • Immunohistology
    • Histology Positive Control Tissue
    • Histology Positive Control Tissue
    • Histology Positive Control Tissue
    • Immunofluorescence
    • Immunofluorescence
    • Immunofluorescence
    • Western Blotting
    • Western Blotting
    • Western Blotting
    • Instructions For Use
      1.To the antibody sample add 1ul of the Rapid Plus Modifier reagent for every 10ul of antibody and mix gently.

      2.Pipette the mixed antibody-modifier sample directly onto the LYNXTM Rapid Plus lyophilized mix and gently pipette up and down twice to resuspend.

      3.Replace cap onto vial and incubate in the dark at room temperature (20-25oC) for 15 minutes, or overnight if preferred.

      4.After incubation, add 1ul of Rapid Plus Quencher reagent for every 10ul of antibody used, and mix gently. Leave to stand for 4 minutes before use.

    • Instructions For Use
      1.To the antibody sample add 1ul of the Rapid Plus Modifier reagent for every 10ul of antibody and mix gently.

      2.Pipette the mixed antibody-modifier sample directly onto the LYNXTM Rapid Plus lyophilized mix and gently pipette up and down twice to resuspend.

      3.Replace cap onto vial and incubate in the dark at room temperature (20-25oC) for 15 minutes, or overnight if preferred.

      4.After incubation, add 1ul of Rapid Plus Quencher reagent for every 10ul of antibody used, and mix gently. Leave to stand for 4 minutes before use.

    • Instructions For Use
      1.To the antibody sample add 1ul of the Rapid Plus Modifier reagent for every 10ul of antibody and mix gently.

      2.Pipette the mixed antibody-modifier sample directly onto the LYNXTM Rapid Plus lyophilized mix and gently pipette up and down twice to resuspend.

      3.Replace cap onto vial and incubate in the dark at room temperature (20-25oC) for 15 minutes, or overnight if preferred.

      4.After incubation, add 1ul of Rapid Plus Quencher reagent for every 10ul of antibody used, and mix gently. Leave to stand for 4 minutes before use.

    Additional Rhodamine Conjugation Kit Formats

    Formats Applications Sizes available
    Rhodamine Conjugation Kit : Kit CJ 3 Conjugations For 20µg Antibody | 1 Conjugation For 2mg Antibody | 3 Conjugations For 200µg Antibody
    • Copyright © 2016 Bio-Rad

    Recommended Secondary Antibody

      Recommended Negative Isotype Control

        Useful Reagents

          Recommended Positive Controls

            Histology Controls

              Write your review

              You may also be interested in...